Palma Vita Technical

Electrical Services
Electrical installation should be in accordance with I.E.E. Regulations (Current Edition).

• 220/240v single phase AC supply is required, (loading 10 amp, maximum power 1300 watts).The Clos-o-Mat is supplied with 3 core cable attached. A fused spur is required for isolation.
• Spur outlet to be located in accordance with current I.E.E. Regulations (Current Edition).
• Clos-o-Mat has IPX4 rating.

Bathroom/Shower Room Installations
• The Clos-o-Mat must not be in direct line with the shower spray. Some form of partition between shower and Clos-o-Mat is advisable to prevent any water spraying directly onto the equipment.
• A shower should not be used in conjunction with the Clos-o-Mat. i.e. under no circumstances must a user shower whilst seated on the Clos-o-Mat.

Water Services
• It is essential that the entering water is cold.
• 15mm cold water service only.
• We would recommend water supply isolated via isolation valve.
• Water supply can be from level storage or mains.
• Boiler Capacity: 1.7 litres.
• Water rate: min. 8 l/min. max. 0.8 PMa (8 bar).
• Cistern capacity: 6-9 litres, set at 6 litres.

Overflow
• The Clos-o-Mat has an internal overflow which discharges into the W.C. pan through the flush valve.

Soil Connection
• Relevant soil connector to be sourced by installer.
• Soil connections suitable for Clos-o-Mat; S-Trap (vertical fall) wall to centre of pipe from 70mm-250mm max. P-Trap (horizontal) floor to centre of pipe 200mm max.
• The Clos-o-Mat is suitable for all turned trap outlets, through purpose made removable side covers on lower level.

Further Notes
• No permanent hand rails or other obstructions should be fitted across the front or top of the unit.The white outer casing has to be pulled upwards and forward to remove for servicing purposes.
• If extended douche option is specified, space must be made to accommodate douche arm which extends beyond rear of casing. Optional infill panel available to avoid the need to chase wall. Unit can be fitted away from rear wall if required.

Infill Panel
The infill panel specifications are printed on the inside of the rear cover.

Technical Drawings
Click here to download CAD drawings >



Dimensions are in mm and not to scale.

Back >